Thin Layer Chromatography for Composition of Analgesics

Thin Layer Chromatography for Composition of AnalgesicsTHIN LAYER CHROMATOGRAPHYHALILI, Johanna Bernadette C.ABSTRACTIn this taste, a thin-layer chromatography (tender loving care) was utilize to determine the composition of several(predicate) analgesic drugs which were Aspirin, Ibuprofen, Caffeine, Paracetamol, tea leaf sample and an noncitizen substance. Chromatography takes advantage of the fact that different substances are agencyiti unmatchabled between two phases. TLC is utilise to identify individual components in a mixture. These chromatography techniques concentrate on the fact that components of a mixture tend to move at different speeds along the at once surface from the paper utilise to separate from from from each one one(prenominal) other. The results obtained by comparing the descry and after playing the experiment, the inglorious was identified to be Aspirin.INTRODUCTIONThin-layer chromatography (TLC) is one of the most important techniques in organic alchemy and is used for the rapid separation and qualitative analysis of different substances (Pavia, et. al., 2010). This separation technique is accomplished by the combination of the mixture between two phases the stationary and the agile phase. The stationary phase or the absorbent, which is ordinarily silica or alumina, is coated on a supporting material which is either a nut or plastic. The sample is applied to the layer of the adsorbent coated sheet or TLC scale leaf. The mobile phase, or the declaration called the eluant, travels up the absorbent by capillary action (Ault, 1998 Miller, 2005). As the reply passes by means of the sample or role, it shows the effects of separation of the material in the skin senses. This separation technique is also used to identify if substances are pure and to compare it with other samples. Unknown substances buttocks be also fixed by comparing an unnamed immixs behavior with the other known substances.In this experiment, thin-l ayer chromatography is used to determine the qualitative compositions of over-the-counter analgesic drugs. The objectives for the experiment are to observe the different analgesic drugs, to carry through thin-layer chromatography and calculate Rf values and to use thin-layer chromatography to identify the analgesic compound present in an unknown sample.METHODOLOGYThe group prepared a bedroom for the experiment of thin layer chromatography for analgesic drugs. The chamber consists of a dribble paper wrapped virtually the 50 ml beaker with a small spring left for viewing. A 3 ml outcome mixture (25 parts ethyl acetate, 1 part ethanol, and 1 part acetic acid) was added to the chamber and was later covered using a watch churl to provide an atmosphere saturated with solvent inside the container. The filter paper was moistened for the solvent to rise equally. piece of music the chamber was set aside, a silica gel coated TLC musical scale was obtained and using a pencil, a very lig ht line was drawn across the sheet, about 10 mm from one end Seven small light marks were made along the line and labelled A to G. Each letter correspond to seven analgesic drugs which are aspirin, ibuprofen, caffeine, paracetamol, sample tea extract hoard from one previous experiment, an unknown substance and co-spot respectively. Using a capillary thermionic vacuum tube, small vagabond of each sample was seatd exactly in the intersection of the even line and the tick marks for each letter to make sure it will not mix with the other samples. The capillary tube was cleaned by using Dichloromethane and it was done three times. For the sample E or the tea extract from the experiment Isolation of caffeine from tea leaves, the filter paper that contained the caffeine extracts was rinsed with dichloromethane to be able to prepare a spot to the TLC. The spots on the TLC central office were allowed to dry for 1-2 minutes.As soon as the spots were dry, the TLC plate was dropped vert ically to an upright position making sure that the chamber is on a stationary place and was covered again using a watch glass. The liquid slowly locomote up the TLC sheet. When 80-90% of the solvent had already gone up of the TLC plate, the TLC plate was immediately removed taking note of where the solvent was last seen. Immediately, the TLC plate was marked where the solvent was last seen. The plate was air-dried and it was observed under UV light to point out where the spots are. While observing under the UV lamp, a light pencil mark was marked around each spot in the TLC plate.RESULTS AND DISCUSSIONResultsFigure 1. Silica Gel coated TLC plate results.Figure 2. Silica Gel coated TLC plate results under UV light. get across 1. Measurement of the distances of the spots in the TLC plate and lookd Rf values.Distance travelled by the solvent 30.0 mmDiscussionThe objective of this experiment was to perform thin layer chromatography to test a trustworthy substance of its righteousnes s or impurity and also to know the analgesic present in an unknown substance. The results shows that 5 out of 7 analgesics had 2 or more spots which indicates that are impurities or in that respect are different compounds in those analgesic drugs. The different analgesic drugs that were observed to have 2 or more spots were Aspirin, Ibuprofen, Paracetamol, the unknown substance and the co-spot.Rf values were also computed by the distance (in mm) travelled by the solvent was measured exactly from the horizontal line drawn up to where it was last seen when it moved up. The spots were also measured and for those samples that had 2 or more spots, each spots were measured individually.The comparison used for solving the Rf value isFor accuracy, the distance travelled by the spot was measured from the horizontal line up to the center of the spot.Rf values were used to compare the substances and identify the analgesic compound present in an unknown sample. Similarities was observed betwe en Aspirin and the unknown analgesic drug F since their spots are very convertible and their Rf values are very close to each other with only a 0.004 mm difference. Also, the results show that the caffeine extracted from the experiment Isolation of caffeine from tea leaves is indeed caffeine since spot C or pure caffeine is very similar because the spot produced by the tea extract and this is evident since it is indicated in their Rf values that they are very similar to each other.In comparing compounds used in the experiment run, the group observed that compounds with the larger Rf are less polar because it interacts less strongly with the polar adsorbent on the TLC plate (Ault, 1998). The experiment went as expected with no unusual events that would have introduced error. The group was able to perform the thin-layer chromatography and to compute for the different Rf values.CONCLUSIONThin-layer chromatography (TLC) was the technique used to determine the composition of various ove r-the-counter analgesics and the purity of the different substances which were Aspirin, Ibuprofen, Caffeine, Paracetamol, tea sample from one of our previous experiment and an unknown sample. With thin-layer chromatography, it was identified that compounds with the larger Rf are less polar because it interacts less strongly with the polar adsorbent on the TLC plate, and compounds with a smaller Rf values are more polar. It was also observed that the tea sample pull together from one of our previous experiment was indeed pure caffeine because of the similarities of the spots and Rf values of the spot C and pure caffeine. The different analgesic drugs that were observed to have 2 or more spots were Aspirin, Ibuprofen, Paracetamol, the unknown substance and the co-spot. Two or more spots were observed because of impurities or it contains different substances. Lastly, the unknown sample in the TLC plate was observed to be Aspirin because of the similarities of the measurement of the sp ot and Rf values which only had a difference of 0.004 mm.RECOMMENDATIONSTo obtain a better result of the experiment, the different techniques can be done. One technique that can be done is a volatile solvent want 25 parts ethyl acetate, 1 part ethanol, and 1 part acetic acid. The TLC plate is very sensitive to different materials or compounds and it is important not to touch the TLC plate to turn a dash contamination of oil from the hands. In collecting different sample, one should remember to wash capillary tube with dichloromethane not less than three times to avoid contamination. To place appropriate size of each spot so it wont mix with the other spots. For light/dull colored samples, it is recommended to place spots up to three times for it to be visible. In preparing the chamber, one should moisten properly the filter paper to have equal rising of the solvent and cover all the times the chamber since the solvent is volatile. Lastly, drop properly making sure it falls in an u pright postion or the TLC plate should lean to the filter paper and remember not move the chamber in any way to avoid unequal rising of the solvent to the TLC plate.REFERENCESAult, A. Techniques and Experiments for Organic Chemistry, 6th ed. University Science Books, California, 1998.Miller, J. Chromatography Concepts and Contrasts, 2nd ed. jakes Wiley Sons, Inc. Publication, 2005.Pavia, D., Lampman, G., Kriz, G., Engel, R. A Small Scale Approach to Organic Laboratory Techniques, 3rd ed. Cengage Learning, United States of America, 2010.

No comments:

Post a Comment